Hog Slat Inc. Newton Grove, NC USA August 2016 7 Ventilation Systems 4. DO NOT OPERATE MACHINE while hanging on this bolt. Level machine and secure machine using 3/8” x 2” Lag bolts (supplied) in the (6) mounting locations. (Figure 2) Figure 2 5. When connecting cables, the load nut should be near the “Closed” position to allow enough cable for manual winch connection. 6. Run cable ends through side of machine around pulley down to the load block. Route cables around pulleys as shown in figures 3,4 and 5 that best suits the application. (4) Inside chassis mounting locations (2) External Mounting Locations If mounting does not allow the use of these locations, install 3/8“ to 1/2” diameter bolts with nuts in the holes to secure internal thrust plate to machine cabinet. Failure to secure the thrust plate could result in plate damage during heavy-load conditions.