GrowerSELECT® Installation Manuals Binder
Hog Slat Inc. Newton Grove, NC USA May 2017 39 GROW-DISK ™ Feed System GrowerSELECT™ HS11 Feed Sensor Specifications: Operating Voltage: 20-250 VAC/DC Frequency: 50-60 Hz Output Current max: 330 mA Sensitivity: 3/32”.3/4” [2…20mm] Ambient Operating Temperature: -13°F-+158°F [-25…+70°C] Cord: Length= 6’ [2m] 2 x .75mm 2 The HS11 Feed Sensor is used to signal the chain disk system controller when the feed system is full and to shut off the chain disk system drive unit. The HS11 is mounted in the chain disk feed tube after the last drop or mounted in the last drop tube depending upon application. These instructions are a guideline for installation of the GrowerSelect Chain Disk System Feed Sensor (2) wire (Current Robbing) application for use with GrowerSelect Chain Disk Controllers and other Controllers utilizing (2) wire proximity switch inputs non-time delay. In all cases, the OEM (Original Equipment Manufacturer) wiring instructions should be followed if possible when connecting the HS11 to controller inputs. It is in no way to be used to violate or supersede local, state and national wiring codes. All wiring sizes and fuse capacities are to be sized according to national electrical code specifications or other applicable regulations. Feed sensor switch is switchable from Normally Open (NO) to Normally Closed (NC) depending upon application. Sensor is factory set to NO. Selector Switch Sensitivity Adjustment LED Indicator Water Tight Service Plug HS11