Hog Slat Inc. Newton Grove, NC USA May 2017 49 GROW-DISK ™ Feed System Maintenance Safety Switch Inspection • Disconnect power and remove drive unit cover. • Move safety switch roller in one direction so that safety switch is activated and blue reset button is tripped. • Replace cover and turn power back on. • Put the HSCD-100 Controller into the manual start position. If alarm indication is displayed, then safety switch is working properly. If not, disconnect power, inspect wiring and safety switch, and replace if necessary. • Turn power back off, remove cover, and pull blue reset button out to normal position. • Replace cover, power unit back on, turn the Controller to manual stop, and acknowledge alarm on Controller is off. • System is ready for normal operation.